Description
Reference standards: UNI EN ISO 12625-5: 2017
Sample dimensions: 50 ± 0.5X200mm
Initial span tensile tester clamps: 100mm
Water immersion time: 15 sec.
Immersion depth in water: 20mm
Constant rate elongation speed: 50 ± 2mm / min.
FOR TESTS OF WET RESISTANCE OF TISSUE PAPERS
Reference standards: UNI EN ISO 12625-5: 2017
Sample dimensions: 50 ± 0.5X200mm
Initial span tensile tester clamps: 100mm
Water immersion time: 15 sec.
Immersion depth in water: 20mm
Constant rate elongation speed: 50 ± 2mm / min.